Add Time: 2026-11-12 View:82
This vacuum degreasing furnace is equipped with a secondary heating chamber, a 1-way float flowmeter, integrated exhaust gas combustion, strong induced draft system, and chamber pressure detection function, mainly used for the process of body degreasing. The equipment adds a secondary heating chamber on the basis of the main degreasing chamber to preheat and decompose the degreasing volatiles, thereby improving the removal efficiency; Accurately control the intake flow rate of protection/carrier...
| Equipment Features: Configure a secondary heating chamber to fully crack volatile compounds, reduce carbon buildup in pipelines, and achieve more thorough degreasing Single channel float flowmeter, intuitive and stable control of carrier gas flow, simple operation Equipped with a built-in exhaust combustion device, the organic waste gas is fully incinerated to meet environmental emission requirements Strong induced draft system combined with real-time detection of chamber pressure, adjustable and controllable pressure, to suppress oxygen reflux Vacuum degreasing environment, uniform degreasing, less likely to crack or bubble the billet Compact structure, complete safety interlock, stable operation, and convenient maintenance | |
Device Model | M1500-22+TIFYW | |
Electrical specifications | AC220V/5.7KW | |
Box furnace maximum temperature/rated temperature | 1500℃/1450℃ | |
sensor type | S型 | |
Touch screen size | 7" | |
Recommended heating rate | ≤10℃ | |
Dimensions of the temperature zone in the box furnace chamber | L220*H220*W260mm | |
Secondary combustion chamber (tube furnace) | Φ80*100mm | |
Secondary combustion chamber thermocouple | K-type thermocouple with a diameter of 1 * 250mm | |
Secondary combustion chamber temperature | ≤1000℃ | |
float flow meter | 0.5-8L/min | |
Range of digital differential pressure gauge | -30~30Pa | |
Equipment external dimensions | L820*H1420*W730mm | |
Equipment weight | about138KG | |
Control System |
| 1. Sintering process curve setting: dynamically display the set curve, and the equipment sintering can pre store multiple process curves, each of which can be freely set; 2. Pre order sintering is available to achieve unmanned sintering process curve sintering; 3. Real time display of sintering power, voltage and other information, recording of sintering data, and the ability to export for paperless recording; 4. Capable of remote control and real-time observation of equipment status; 5. Temperature correction: The difference between the main control temperature and the sample temperature is nonlinearly corrected throughout the sintering process. |
Appointment sintering | ![]() | Optimize equipment utilization, ensure sintering process stability, save waiting time, and achieve efficient and orderly sample preparation. |
Nonlinear temperature correction | ![]() | By using algorithms to nonlinearly correct the temperature deviation between the control point and the sample due to their different positions in the temperature field, the consistency between the control temperature and the sample temperature is improved, the operation is simplified, and the accuracy of experimental data is enhanced. |
Multiple sets of process programs can be preset | ![]() | Multiple sets of experimental exclusive temperature programs can be pre-set to ensure experimental repeatability and ease of operation, support process optimization and data tracing, adapt to team collaboration and technical inheritance, greatly improving experimental efficiency and design flexibility. |
Pressure measurement and monitoring |
| Mechanical pressure gauges are used, and the gauge housing is of an airtight structure, which can effectively protect the internal components from environmental influences and debris intrusion. At the same time, it has strong corrosion resistance and high temperature resistance. |
float flow meter |
| The gas flow rate is controlled by a float flowmeter, which is integrated with the equipment and has undergone leak testing before leaving the factory. |
Equipment usage precautions | When using the equipment, the absolute pressure gauge reading should not exceed 0.15MPa to prevent equipment damage caused by excessive pressure; When used under vacuum, it is recommended that the equipment should not exceed a temperature of 800 ℃. If you have a higher temperature requirement, please contact us for consultation; Before using this device, please carefully read the precautions for using corundum products; | |
Service Support | 1-year warranty with lifetime support (warranty does not include consumable parts such as furnace tubes and seals). | |