3000℃ ultra-high temperature atmosphere furnace
Release time: 2020-6-19 12:07:21 Number of views: 3815
|
Equipment introduction:
|
||
|
|
|
Configuration
Equipment characteristics |
1. The double-layer air-cooled structure greatly reduces the surface temperature of the shell;
|
||||||||
Model |
NBD-HR3000-80TI |
NBD-HR3000-120TI |
|||||||
Electrical Spec |
AC380V 40KW |
AC380V 60KW |
|||||||
Tmax |
2800℃ |
||||||||
Heating rate |
≤20℃/min |
||||||||
Average temperature dimension |
Φ80*100mm |
Φ120*150mm |
|||||||
Control system |
|
1. NBD-101EP embedded operating system interchangeable graphical interface, 7-inch true color touch screen input, intelligent man-machine dialogue mode, real-time heating power display, non-linear pattern temperature correction; The experimental report is generated independently, and the experimental data is exported unlimited times.
|
|||||||
Temp Accuracy |
+/- 1℃ |
||||||||
Heating element
|
|
||||||||
Graphite heater with excellent acid and corrosion resistance |
|||||||||
Cautions |
1, always pay attention to the temperature of the furnace cover, furnace body, furnace bottom and water-cooled electrode, can not be hot, otherwise to stop heating, check whether the water is smooth. 2, if the vacuum degree is not pumped, it should be checked whether the oil in the diffusion pump is oxidized, and whether the mechanical pump is aging, such as aging should be replaced in time. 3, when filling protective gas, attention should be paid to the value of the vacuum pressure gauge, which can not exceed the positive pressure (generally 2-3 cells below 0 and about -50Pa, the furnace is still negative pressure). It should be noted that the gas has the characteristics of thermal expansion, if close to the positive pressure, you can open the mechanical pump and pre-extraction valve to remove part of the gas. 4, when loading, be sure not to touch the graphite heating body (saw seam), because the heating body is fragile after burning, causing unnecessary losses. 5, usually should pay attention to the furnace, outside the furnace cleaning, vacuum valve maintenance work. 6, after opening the pump, pay attention to check whether each valve is fully opened, and the connected water pipe is not dripping, if any, it should be eliminated in time.
|
||||||||
Service |
1 year warranty with lifetime support (warranty does not cover consumable components such as furnace tubes and seals). |
Related products
|
|
|
|
|
|
|
Equipment introduction:
|
||
|
|
|
Configuration
Equipment characteristics |
1. The double-layer air-cooled structure greatly reduces the surface temperature of the shell;
|
||||||||
Model |
NBD-HR3000-80TI |
NBD-HR3000-120TI |
|||||||
Electrical Spec |
AC380V 40KW |
AC380V 60KW |
|||||||
Tmax |
2800℃ |
||||||||
Heating rate |
≤20℃/min |
||||||||
Average temperature dimension |
Φ80*100mm |
Φ120*150mm |
|||||||
Control system |
|
1. NBD-101EP embedded operating system interchangeable graphical interface, 7-inch true color touch screen input, intelligent man-machine dialogue mode, real-time heating power display, non-linear pattern temperature correction; The experimental report is generated independently, and the experimental data is exported unlimited times.
|
|||||||
Temp Accuracy |
+/- 1℃ |
||||||||
Heating element
|
|
||||||||
Graphite heater with excellent acid and corrosion resistance |
|||||||||
Cautions |
1, always pay attention to the temperature of the furnace cover, furnace body, furnace bottom and water-cooled electrode, can not be hot, otherwise to stop heating, check whether the water is smooth. 2, if the vacuum degree is not pumped, it should be checked whether the oil in the diffusion pump is oxidized, and whether the mechanical pump is aging, such as aging should be replaced in time. 3, when filling protective gas, attention should be paid to the value of the vacuum pressure gauge, which can not exceed the positive pressure (generally 2-3 cells below 0 and about -50Pa, the furnace is still negative pressure). It should be noted that the gas has the characteristics of thermal expansion, if close to the positive pressure, you can open the mechanical pump and pre-extraction valve to remove part of the gas. 4, when loading, be sure not to touch the graphite heating body (saw seam), because the heating body is fragile after burning, causing unnecessary losses. 5, usually should pay attention to the furnace, outside the furnace cleaning, vacuum valve maintenance work. 6, after opening the pump, pay attention to check whether each valve is fully opened, and the connected water pipe is not dripping, if any, it should be eliminated in time.
|
||||||||
Service |
1 year warranty with lifetime support (warranty does not cover consumable components such as furnace tubes and seals). |
Related products
|
|
|
|
|
|
- {{item.cat}}
- {{item2.cat}}
- {{ isExpanded[index2] ? 'Retract' : 'More' }}
Phone: 400-000-3746
0371-6320 2805
After-sales service: 0371-6320 2805
MR. CAI: 181-0371-5723
Mr.Gao: 188-3829-0747
Ms.Huang: 188-3829-0748
Email : nbd@nbdkj.com
Address:8# zhuyuan, Xinhua subdistrict, Xinzheng, Zhengzhou, China