Add Time: 2024-06-06 View:826
Equipment Introduction:The 25 station vacuum atmosphere tube furnace is a specialized equipment developed for sintering, melting, analyzing, and producing ceramics, metallurgy, electronics, glass, chemical industry, machinery, refractory materials, new material development, special materials, building materials, metals, non-metals, and other compound materials in higher education institutions, research institutes, and industrial and mining enterprises.25 test tube samples can be sintered simulta...
| Equipment features: | |||||||
Device Name | 25 station vacuum atmosphere tube furnace | |||||||
Specification and model | NBD-T1200-50TI(25管) | |||||||
Tmax | 1200℃ | |||||||
Specification and model | 1150℃ | |||||||
Power supply | three-phase380V 50HZ | |||||||
Rated power | 9KW | |||||||
| Heating temperature zone size | Length 500mm x Height 150mm x Depth 500mm | |||||||
| Temperature measuring element type | Two K-type thermocouples, one for detection and one for control,Φ1*500mm | |||||||
| Extract the size of the vacuum opening | KF40mm | |||||||
| heating rate | 1℃/H-20℃/Min | |||||||
| Size of quartz tube that can be sealed at one end | Φ8-Φ12mm*150mm | |||||||
| Furnace body size | 1315mm long x 1585mm high x 910mm deep | |||||||
Extreme vacuum degree | 5-10pa(If you need a higher vacuum, you can choose a molecular pump) | |||||||
Air inlet and outlet system | Equipped with solenoid valve control, inner and outer polished Ba grade stainless steel pipe with diameter of 6.35 | |||||||
control system |
| 1. Sintering process curve setting: dynamically display the setting curve, the equipment sintering can pre store multiple process curves, and each process curve can be freely set; | ||||||
| Appointment sintering |
| Optimize equipment utilization, ensure sintering process stability, save waiting time, and achieve efficient and orderly sample preparation | ||||||
| Nonlinear temperature correction |
| By using algorithms to nonlinearly correct the temperature deviation between the control point and the sample due to their different positions in the temperature field, the consistency between the control temperature and the sample temperature is improved, the operation is simplified, and the accuracy of experimental data is enhanced. | ||||||
| remote control |
| You can log in to the control system anytime and anywhere through computers, mobile phones, and other terminals to view the operating status of the heating furnace (temperature, pressure, heating rate, etc.), and remotely adjust parameters and start/pause programs according to experimental needs. No need to travel back and forth to the laboratory at night or on holidays to meet the parameter tuning needs during the experimental process; Real time monitoring of key experimental processes can also be achieved during cross regional business trips, significantly reducing ineffective commuting time and allowing researchers to allocate work energy more efficiently. | ||||||
| data storage | ![]() | Ensure data security, integrity, standardized management, and efficient retrieval | ||||||
| Multiple sets of exclusive process programs can be pre-set |
| Multiple types of experiment specific temperature programs can be preset to ensure experimental repeatability and ease of operation, support process optimization and data tracing, adapt to team collaboration and technical inheritance, greatly improving experimental efficiency and design flexibility. | ||||||
Temperature accuracy | ±1℃ | |||||||
Heating element |
| MoDopedFe-Cr-Alalloy | ||||||
Pressure measurement and monitoring |
| Using a mechanical pressure gauge, the outer shell of the gauge is an airtight structure, which can effectively protect the internal components from environmental impact and debris intrusion, and has strong corrosion and high temperature resistance. | ||||||
Gas supply system |
| The gas flow rate is controlled by a float flowmeter, integrated with the equipment, and leak testing has been carried out before leaving the factory. | ||||||
Equipment details | ![]() ![]() | |||||||
Net weight | 360kg | |||||||
Equipment usage precautions | 1. When the furnace temperature of the equipment is ≥ 300 ℃, it is prohibited to open the furnace to avoid injury; | |||||||
Service support | One year limited warranty with lifetime support (warranty does not include consumable parts such as handling pipes and O-rings. Please order replacement parts at the relevant product section below.) | |||||||
Disclaimer: The product introduction content on this website (including product images, product descriptions, technical parameters, etc.) is for reference only. Due to untimely updates, there may be some discrepancies between the described content and the actual situation. Please contact our customer service personnel for confirmation. The information provided on this website does not constitute any offer or commitment, and Novartis may periodically improve and modify any information on the website without prior notice.