Add Time: 2022-07-27 View:1388
The high temperature elastic modulus tester is a test instrument used in the field of material science. It adopts the non-contact response measurement method to obtain the vibration response of the sample surface under pulse excitation, and deduces the elastic modulus of the material through the resonance frequency in reverse. It has the characteristics of non-destructive testing, and evaluates the elastic modulus, shear modulus, Poisson's ratio and damping factor as they change under high t...
Configuration
| 1.High sealing to protect the gas environment, double air outlet design; | ||||||||||||||
Model | NBD-LM1700-22TIF | ||||||||||||||
Electrical Spec | AC220V 4.5KW | ||||||||||||||
Tmax | 1650 ℃ | ||||||||||||||
| Thermocouple type | Type B thermocouple | ||||||||||||||
The heating rate can be reached | ≤ 20 ℃/min | ||||||||||||||
Furnace space | 220×260×220mm | ||||||||||||||
Control system |
| 1. Adopt automatic control mode, touch screen real-time display of equipment data; | |||||||||||||
Temp Accuracy | +/- 1 ℃ | ||||||||||||||
| Appointment sintering |
| Optimize equipment utilization, ensure sintering process stability, save waiting time, and achieve efficient and orderly sample preparation | |||||||||||||
| Nonlinear temperature correction |
| By using algorithms to nonlinearly correct the temperature deviation between the control point and the sample due to their different positions in the temperature field, the consistency between the control temperature and the sample temperature is improved, the operation is simplified, and the accuracy of experimental data is enhanced. | |||||||||||||
| remote control |
| You can log in to the control system anytime and anywhere through computers, mobile phones, and other terminals to view the operating status of the heating furnace (temperature, pressure, heating rate, etc.), and remotely adjust parameters and start/pause programs according to experimental needs. No need to travel back and forth to the laboratory at night or on holidays to meet the parameter tuning needs during the experimental process; Real time monitoring of key experimental processes can also be achieved during cross regional business trips, significantly reducing ineffective commuting time and allowing researchers to allocate work energy more efficiently. | |||||||||||||
| data storage |
| Ensure data security, integrity, standardized management, and efficient retrieval | |||||||||||||
| Multiple sets of exclusive process programs can be pre-set |
| Multiple types of experiment specific temperature programs can be preset to ensure experimental repeatability and ease of operation, support process optimization and data tracing, adapt to team collaboration and technical inheritance, greatly improving experimental efficiency and design flexibility. | |||||||||||||
Heating element | |||||||||||||||
| Four-channel frequency acquisition port |
| ||||||||||||||
Equipment details
|
| ||||||||||||||
gas control
| The float flowmeter is used to control the gas flow rate, which is integrated with the equipment, and the leakage test has been carried out before the factory. | ||||||||||||||
Service | 1 year warranty with lifetime support (warranty does not include consumable parts) | ||||||||||||||
Disclaimer:
The product introduction content of this site (including product pictures, product descriptions, technical parameters, etc.) is for reference only. There may be some difference between the stated content and the actual situation due to the delay in updating. Please contact our customer service staff for confirmation. The information provided by this Site does not constitute any offer or acceptance. NOBODY will improve and modify any information on this site from time to time without prior notice.